Hey there! I’m a supplier of CDL Vertical Multistage Pumps. Over the years, I’ve gotten tons of questions from customers about how to measure the head of these pumps. So, I thought I’d share some tips and tricks on this topic. CDL Vertical Multistage Pump

First off, let’s talk about what "head" means in the context of a CDL Vertical Multistage Pump. Head is basically the height to which a pump can raise water. It’s measured in meters (m) or feet (ft). You can think of it as the pump’s "lifting power." A higher head means the pump can push water up to a greater height.
There are a few different ways to measure the head of a CDL Vertical Multistage Pump. One of the most common methods is using a pressure gauge. Here’s how you do it:
Using a Pressure Gauge
- Install the pressure gauge: First, you need to install a pressure gauge at the discharge port of the pump. Make sure it’s properly connected and sealed to avoid any leaks. You can use a T-fitting to connect the gauge to the discharge pipe.
- Run the pump: Start the CDL Vertical Multistage Pump and let it reach a steady state. This might take a few minutes, depending on the pump’s size and the system it’s connected to.
- Read the pressure: Once the pump is running steadily, look at the pressure gauge. The reading on the gauge is the pressure at the discharge port. But this pressure is in units of pressure (like psi or bar), and we need to convert it to head (in meters or feet).
- Convert pressure to head: To convert the pressure reading to head, you can use the following formulas:
- If the pressure is in psi (pounds per square inch): Head (ft) = Pressure (psi) x 2.31
- If the pressure is in bar: Head (m) = Pressure (bar) x 10
For example, if the pressure gauge reads 50 psi, then the head in feet would be 50 x 2.31 = 115.5 ft.
Measuring Static Head
Another important aspect of measuring the head of a CDL Vertical Multistage Pump is the static head. Static head is the vertical distance between the water source (like a well or a tank) and the point where the water is being discharged.
- Measure the elevation difference: Use a measuring tape or a laser level to measure the vertical distance between the water level in the source and the discharge point. This is the static head.
- Consider the suction lift: If the water source is below the pump, you have a suction lift. You need to add the suction lift to the static head. For example, if the water source is 5 meters below the pump and the discharge point is 10 meters above the pump, the total static head is 15 meters.
Measuring Friction Head
Friction head is the loss of head due to the friction of the water flowing through the pipes, fittings, and valves. It depends on the pipe diameter, length, roughness, and the flow rate of the water.
- Calculate the friction head: There are different methods to calculate the friction head. One common way is to use the Darcy – Weisbach equation or the Hazen – Williams formula. However, these calculations can be a bit complex. A simpler way is to use friction head charts provided by pipe manufacturers.
- Find the flow rate: You need to know the flow rate of the water through the pipes. You can measure the flow rate using a flow meter installed in the pipe. Once you have the flow rate and the pipe characteristics, you can look up the friction head on the chart.
Total Head Calculation
The total head of the CDL Vertical Multistage Pump is the sum of the static head and the friction head.
Total Head = Static Head + Friction Head
Let’s say the static head is 20 meters and the friction head is 5 meters. Then the total head of the pump is 20 + 5 = 25 meters.
Why Measuring Head is Important

Measuring the head of a CDL Vertical Multistage Pump is crucial for several reasons. First, it helps you select the right pump for your application. If you know the required head, you can choose a pump that can provide enough lifting power. Second, it allows you to evaluate the performance of the pump. If the measured head is significantly different from the rated head of the pump, there might be a problem with the pump or the system.
Tips for Accurate Measurement
- Use accurate instruments: Make sure your pressure gauge and flow meter are calibrated correctly. Inaccurate instruments can lead to wrong measurements.
- Check for leaks: Leaks in the pipes or fittings can affect the pressure and flow rate, leading to inaccurate head measurements.
- Measure at steady state: Wait for the pump to reach a steady state before taking any measurements. This ensures that the readings are reliable.
Conclusion
Self-Priming Sewage Pump Measuring the head of a CDL Vertical Multistage Pump is an important part of pump selection and performance evaluation. By using the methods I’ve described above, you can get an accurate measurement of the head. If you’re in the market for a CDL Vertical Multistage Pump or need more information about head measurement, feel free to reach out for a procurement discussion. We’re here to help you find the right pump for your needs.
References
- Fluid Mechanics textbooks
- Pump manufacturer’s manuals